Clean Room Engineering

Introduction

“Room with a defined concentration of airborne particles, designed and used in a way that the number of particles introduced into the room or originating and being deposited in the room is as small as possible, and in which other cleanliness-relevant parameters such as temperature, humidity and pressure can be controlled as required”

CLEANROOMS OVERVIEW

Clean Rooms are used where small particles can adversely impact the manufacturing process and the quality and hygiene of the manufactured product. Clean rooms help in reducing the contamination caused by particles and control the environmental parameters such as temperature, humidity and pressure. The most important component of clean rooms is the HEPA filter, which assists in reducing particles that are 0.3 micron and larger in size.

Air in the enclosed room is passed through the clean room and the HEPA filters. In some cases where rigorous cleanliness is essential, the Ultra-Low Particulate Air (ULPA) filters are used in the cleanrooms process.

It is of utmost importance for the personnel to undergo a training process to control the contamination in the clean room. They should always enter the clean room with a must wear special clothing, which is designed to not expose contamination that are naturally released or generated by skin and body.

ISO Clean Room Classifications

Clean room classifications are on the basis of how clean the air is in the enclosed area. As per the Federal Standard 209 (A to D) of the USA, the number of particles equal to and greater than 0.5 µm is measured in one cubic foot of air, and this is used as a benchmark for ISO cleanroom classification. This is also acceptable in the Federal Standard 209E version, which is used domestically. The latest version of the standard is TC 209 from the International Standards Organization and both of these standards classify clean rooms on the basis of the number of particles found in the area’s air.

Clean Room Classification is based on the number and size of particles permitted per volume of air in an enclosed area. Large numbers like “class 100” or “class 1000” refer to FED_STD-209E, which refers to the number of particles of size 0.5 µm or larger permitted per cubic foot of air.

As per Federal Standards 209E and ISO 14644-1, there is a log-log relationship between particle size and its concentration, which concludes that there is nothing as a 0 particle concentration. The ordinary room air falls under approx. Class 10,00,000 or ISO 9 clean room classification.

Class

Maximum
Particles/m3

FED STD 209E

>=0.1 µm

>=0.2 µm

>=0.3 µm

>=0.5 µm

>=1 µm

>=5 µm

equivalent

ISO 1

10

2

     

ISO 2

100

24

10

4

   

ISO 3

1,000

237

102

35

8

 

Class 1

ISO 4

10,000

2,370

1,020

352

83

 

Class 10

ISO 5

100,000

23,700

10,200

3,520

832

29

Class 100

ISO 6

1,000,000

237,000

102,000

35,200

8,320

293

Class 1,000

ISO 7

   

352,000

83,200

2,930

Class 10,000

ISO 8

   

3,520,000

832,000

29,300

Class 100,000

ISO 9

   

35,200,000

8,320,000

293,000

Room Air

We provide best solution for engineering and design, clean room partitioning, HVAC system equipment. We are the best turnkey solution provider in India. We have latest design and technology, high quality range with an ideal line of products and services that would save your money and time.

Basic Services:

  • Conceptual basic & detailed design and engineering.
  • Cleanroom preparation (Ducting, HVAC, etc.)
  • Clean and black utility piping.
  • Cleanroom equipments (HEPA, LAF, Air Shower, etc.)